Check of Modelica.Electrical.Analog.Examples.DemoPowerSupply
The model has the same number of unknowns and equations: 24
Check of Modelica.Electrical.Analog.Examples.DemoPowerSupply successful.
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225023730 | 20250224233152 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 3.58 | 3.59 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica_org\Modelica.Electrical.Analog.Examples.DemoPowerSupply\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica\Modelica.Electrical.Analog.Examples.DemoPowerSupply\WorkDir |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.52 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 2.53 s | 2.53 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 0 | 0 |
| Number NL equation systems | 1 | 1 |
| Largest NL equation system | 1 | 1 |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.51 s |
| Simulation time | 1.00 s | 1.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 1 | 1 |
| State Events | 2 | 2 |
| Jacobian evaluations | 65 | 65 |
| Integrator Steps | 68 | 68 |
| Total CPU time | 0.02 s | 0.02 s |
| CPU time Integration | 0.02 s | 0.02 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of Modelica.Electrical.Analog.Examples.DemoPowerSupply
The model has the same number of unknowns and equations: 24
Check of Modelica.Electrical.Analog.Examples.DemoPowerSupply successful.
check - Open log
Check of Modelica.Electrical.Analog.Examples.DemoPowerSupply
The model has the same number of unknowns and equations: 24
Check of Modelica.Electrical.Analog.Examples.DemoPowerSupply successful.
translate - Open log
Translation of Modelica.Electrical.Analog.Examples.DemoPowerSupply
The DAE has 24 scalar unknowns and 24 scalar equations.
Statistics
Original Model
Number of components: 6
Variables: 43
Parameters: 19 (19 scalars)
Unknowns: 24 (24 scalars)
Equations: 25
Nontrivial: 22
Translated Model
Constants: 7 scalars
Free parameters: 12 scalars
Parameter depending: 4 scalars
Time-varying variables: 9 scalars
Alias variables: 11 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {2}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Finished
translate - Open log
Translation of Modelica.Electrical.Analog.Examples.DemoPowerSupply
The DAE has 24 scalar unknowns and 24 scalar equations.
Statistics
Original Model
Number of components: 6
Variables: 43
Parameters: 19 (19 scalars)
Unknowns: 24 (24 scalars)
Equations: 25
Nontrivial: 22
Translated Model
Constants: 7 scalars
Free parameters: 12 scalars
Parameter depending: 4 scalars
Time-varying variables: 9 scalars
Alias variables: 11 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {2}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 1
translate - Largest NL equation system
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:00:40 2025)
dymosim started
... "Modelica.Electrical.Analog.Examples.DemoPowerSupply" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1
CPU-time for integration : 0.018 seconds
CPU-time for one grid interval : 0.0018 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 10006
Number of grid points : 10001
Number of accepted steps : 68
Number of f-evaluations (dynamics) : 68
Number of crossing function evaluations : 10079
Number of Jacobian-evaluations : 65
Number of model time events : 1
Number of input time events : 0
Number of state events : 2
Number of step events : 0
Minimum integration stepsize : 4.31e-08
Maximum integration stepsize : 0.419
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Electrical.Analog.Examples.DemoPowerSupply
simulate - Open log
Log-file of program ./dymosim
(generated: Mon Feb 24 23:55:47 2025)
dymosim started
... "Modelica.Electrical.Analog.Examples.DemoPowerSupply" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1
CPU-time for integration : 0.016 seconds
CPU-time for one grid interval : 0.0016 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 10006
Number of grid points : 10001
Number of accepted steps : 68
Number of f-evaluations (dynamics) : 68
Number of crossing function evaluations : 10079
Number of Jacobian-evaluations : 65
Number of model time events : 1
Number of input time events : 0
Number of state events : 2
Number of step events : 0
Minimum integration stepsize : 4.31e-08
Maximum integration stepsize : 0.419
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Electrical.Analog.Examples.DemoPowerSupply