Check of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier
The model has the same number of unknowns and equations: 251
Check of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier successful.
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225023730 | 20250224233152 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 4.13 | 4.13 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica_org\Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica\Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier\WorkDir |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.02 s | 1.02 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 2.55 s | 2.54 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 4 | 4 |
| Number NL equation systems | 1 | 1 |
| Largest NL equation system | 2 | 2 |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.52 s |
| Simulation time | 1.00 s | 1.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 50 | 50 |
| State Events | 100 | 100 |
| Jacobian evaluations | 2007 | 2109 |
| Integrator Steps | 7557 | 7655 |
| Total CPU time | 0.13 s | 0.17 s |
| CPU time Integration | 0.12 s | 0.17 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier
The model has the same number of unknowns and equations: 251
Check of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier successful.
check - Open log
Check of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier
The model has the same number of unknowns and equations: 251
Check of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier successful.
translate - Open log
Translation of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier
The DAE has 251 scalar unknowns and 251 scalar equations.
Statistics
Original Model
Number of components: 71
Variables: 360
Constants: 8 (8 scalars)
Parameters: 104 (104 scalars)
Unknowns: 248 (251 scalars)
Differentiated variables: 6 scalars
Equations: 213
Nontrivial: 178
Translated Model
Constants: 52 scalars
Free parameters: 55 scalars
Parameter depending: 32 scalars
Outputs: 2 scalars
Continuous time states: 4 scalars
Time-varying variables: 81 scalars
Alias variables: 143 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {16}
Sizes after manipulation of the linear systems: {4}
Sizes of nonlinear systems of equations: {9}
Sizes after manipulation of the nonlinear systems: {2}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
iAC.mean1.x
iAC.mean2.x
iDC2.mean.x
voltageQS.pin_p.reference.gamma
Finished
translate - Open log
Translation of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier
The DAE has 251 scalar unknowns and 251 scalar equations.
Statistics
Original Model
Number of components: 71
Variables: 360
Constants: 8 (8 scalars)
Parameters: 104 (104 scalars)
Unknowns: 248 (251 scalars)
Differentiated variables: 6 scalars
Equations: 213
Nontrivial: 178
Translated Model
Constants: 52 scalars
Free parameters: 55 scalars
Parameter depending: 32 scalars
Outputs: 2 scalars
Continuous time states: 4 scalars
Time-varying variables: 81 scalars
Alias variables: 143 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {16}
Sizes after manipulation of the linear systems: {4}
Sizes of nonlinear systems of equations: {9}
Sizes after manipulation of the nonlinear systems: {2}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
iAC.mean1.x
iAC.mean2.x
iDC2.mean.x
voltageQS.pin_p.reference.gamma
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 2
translate - Largest NL equation system
- 2
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:02:02 2025)
dymosim started
... "Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1
CPU-time for integration : 0.125 seconds
CPU-time for one grid interval : 0.0125 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 10212
Number of grid points : 10001
Number of accepted steps : 7557
Number of f-evaluations (dynamics) : 13875
Number of crossing function evaluations : 18607
Number of Jacobian-evaluations : 2007
Number of model time events : 50
Number of input time events : 0
Number of state events : 100
Number of step events : 0
Minimum integration stepsize : 5.51e-11
Maximum integration stepsize : 0.00167
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier
simulate - Open log
Log-file of program ./dymosim
(generated: Mon Feb 24 23:57:13 2025)
dymosim started
... "Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1
CPU-time for integration : 0.168 seconds
CPU-time for one grid interval : 0.0084 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 20212
Number of grid points : 20001
Number of accepted steps : 7655
Number of f-evaluations (dynamics) : 13976
Number of crossing function evaluations : 28688
Number of Jacobian-evaluations : 2109
Number of model time events : 50
Number of input time events : 0
Number of state events : 100
Number of step events : 0
Minimum integration stepsize : 5.51e-11
Maximum integration stepsize : 0.00167
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.Rectifier