Check of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter
The model has the same number of unknowns and equations: 76
Check of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter successful.
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225023730 | 20250224233152 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 4.14 | 4.62 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica_org\Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica\Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter\WorkDir |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.02 s | 1.02 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 2.55 s | 3.05 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 2 | 2 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.53 s | 0.51 s |
| Simulation time | 0.00 s | 0.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 4 | 4 |
| State Events | 0 | 0 |
| Jacobian evaluations | 202 | 325 |
| Integrator Steps | 1607 | 2300 |
| Total CPU time | 0.01 s | 0.01 s |
| CPU time Integration | 0.01 s | 0.01 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter
The model has the same number of unknowns and equations: 76
Check of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter successful.
check - Open log
Check of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter
The model has the same number of unknowns and equations: 76
Check of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter successful.
translate - Open log
Translation of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter
The DAE has 76 scalar unknowns and 76 scalar equations.
Statistics
Original Model
Number of components: 15
Variables: 364
Constants: 5 (5 scalars)
Parameters: 283 (283 scalars)
Unknowns: 76 (76 scalars)
Differentiated variables: 2 scalars
Equations: 53
Nontrivial: 44
Translated Model
Constants: 291 scalars
Free parameters: 10 scalars
Parameter depending: 3 scalars
Continuous time states: 2 scalars
Time-varying variables: 31 scalars
Alias variables: 29 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {3}
Sizes after manipulation of the linear systems: {0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
Q1.vbc
Q1.vbe
Finished
translate - Open log
Translation of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter
The DAE has 76 scalar unknowns and 76 scalar equations.
Statistics
Original Model
Number of components: 15
Variables: 364
Constants: 5 (5 scalars)
Parameters: 283 (283 scalars)
Unknowns: 76 (76 scalars)
Differentiated variables: 2 scalars
Equations: 53
Nontrivial: 44
Translated Model
Constants: 291 scalars
Free parameters: 10 scalars
Parameter depending: 3 scalars
Continuous time states: 2 scalars
Time-varying variables: 31 scalars
Alias variables: 29 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {3}
Sizes after manipulation of the linear systems: {0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
Q1.vbc
Q1.vbe
Finished
translate - Largest NL equation system
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:02:16 2025)
dymosim started
... "Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
... Warning message from dymosim
At time T = 2.149259e-15 in current integration interval
T_interval = 0.000000e+00 ... 1.001001e-10
a large amount of work has been expended
(about 500 steps) in the integrator. Probably the communication
interval is too large or the system is stiff.
Integration terminated successfully at T = 1e-07
CPU-time for integration : 0.005 seconds
CPU-time for one grid interval : 0.00501 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 1005
Number of grid points : 1000
Number of accepted steps : 1607
Number of f-evaluations (dynamics) : 3368
Number of Jacobian-evaluations : 202
Number of model time events : 4
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 6.32e-17
Maximum integration stepsize : 1.78e-09
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter
simulate - Open log
Log-file of program ./dymosim
(generated: Mon Feb 24 23:57:28 2025)
dymosim started
... "Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
... Warning message from dymosim
At time T = 1.354789e-17 in current integration interval
T_interval = 0.000000e+00 ... 5.002501e-11
a large amount of work has been expended
(about 500 steps) in the integrator. Probably the communication
interval is too large or the system is stiff.
Integration terminated successfully at T = 1e-07
CPU-time for integration : 0.01 seconds
CPU-time for one grid interval : 0.005 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 2005
Number of grid points : 2000
Number of accepted steps : 2300
Number of f-evaluations (dynamics) : 4825
Number of Jacobian-evaluations : 325
Number of model time events : 4
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 7.33e-18
Maximum integration stepsize : 1.31e-09
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Electrical.Spice3.Examples.Spice3BenchmarkRtlInverter