Check of Modelica.Fluid.Examples.PumpingSystem
The model has the same number of unknowns and equations: 307
Check of Modelica.Fluid.Examples.PumpingSystem successful.
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225023730 | 20250224233152 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 7.19 | 6.65 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica_org\Modelica.Fluid.Examples.PumpingSystem\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica\Modelica.Fluid.Examples.PumpingSystem\WorkDir |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 2.04 s | 1.52 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 4.09 s | 3.57 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 2 | 2 |
| Continuous time states | 5 | 5 |
| Number NL equation systems | 3 | 3 |
| Largest NL equation system | 1 | 1 |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.02 s | 1.52 s |
| Simulation time | 2000.00 s | 2000.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 6 | 6 |
| State Events | 12 | 12 |
| Jacobian evaluations | 385 | 477 |
| Integrator Steps | 1236 | 1714 |
| Total CPU time | 0.62 s | 0.98 s |
| CPU time Integration | 0.62 s | 0.98 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of Modelica.Fluid.Examples.PumpingSystem
The model has the same number of unknowns and equations: 307
Check of Modelica.Fluid.Examples.PumpingSystem successful.
check - Open log
Check of Modelica.Fluid.Examples.PumpingSystem
The model has the same number of unknowns and equations: 307
Check of Modelica.Fluid.Examples.PumpingSystem successful.
translate - Open log
Translation of Modelica.Fluid.Examples.PumpingSystem
The DAE has 307 scalar unknowns and 307 scalar equations.
Statistics
Original Model
Number of components: 45
Variables: 558
Constants: 60 (60 scalars)
Parameters: 187 (183 scalars)
Unknowns: 311 (307 scalars)
Differentiated variables: 10 scalars
Equations: 229
Nontrivial: 183
Translated Model
Constants: 191 scalars
Free parameters: 58 scalars
Parameter depending: 74 scalars
Continuous time states: 5 scalars
Time-varying variables: 91 scalars
Alias variables: 136 scalars
Number of mixed real/discrete systems of equations: 4
Sizes of linear systems of equations: {7, 3}
Sizes after manipulation of the linear systems: {2, 2}
Sizes of nonlinear systems of equations: {7, 3, 2}
Sizes after manipulation of the nonlinear systems: {1, 1, 1}
Number of numerical Jacobians: 2
Initialization problem
Number of mixed real/discrete systems of equations: 2
Sizes of nonlinear systems of equations: {7, 2}
Sizes after manipulation of the nonlinear systems: {1, 1}
Sizes of simplified homotopy nonlinear systems of equations: {4}
Sizes after manipulation of the simplified homotopy nonlinear systems: {1}
Number of numerical Jacobians: 2
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
PT1.y
pumps.medium.p
pumps.medium.T
reservoir.level
reservoir.medium.T
Finished
translate - Open log
Translation of Modelica.Fluid.Examples.PumpingSystem
The DAE has 307 scalar unknowns and 307 scalar equations.
Statistics
Original Model
Number of components: 45
Variables: 558
Constants: 60 (60 scalars)
Parameters: 187 (183 scalars)
Unknowns: 311 (307 scalars)
Differentiated variables: 10 scalars
Equations: 229
Nontrivial: 183
Translated Model
Constants: 191 scalars
Free parameters: 58 scalars
Parameter depending: 74 scalars
Continuous time states: 5 scalars
Time-varying variables: 91 scalars
Alias variables: 136 scalars
Number of mixed real/discrete systems of equations: 4
Sizes of linear systems of equations: {7, 3}
Sizes after manipulation of the linear systems: {2, 2}
Sizes of nonlinear systems of equations: {7, 3, 2}
Sizes after manipulation of the nonlinear systems: {1, 1, 1}
Number of numerical Jacobians: 2
Initialization problem
Number of mixed real/discrete systems of equations: 2
Sizes of nonlinear systems of equations: {7, 2}
Sizes after manipulation of the nonlinear systems: {1, 1}
Sizes of simplified homotopy nonlinear systems of equations: {4}
Sizes after manipulation of the simplified homotopy nonlinear systems: {1}
Number of numerical Jacobians: 2
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
PT1.y
pumps.medium.p
pumps.medium.T
reservoir.level
reservoir.medium.T
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 1
- 1
- 1
translate - Largest NL equation system
- 1
- 1
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:04:03 2025)
dymosim started
... "Modelica.Fluid.Examples.PumpingSystem" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2000
CPU-time for integration : 0.616 seconds
CPU-time for one grid interval : 0.123 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5032
Number of grid points : 5001
Number of accepted steps : 1236
Number of f-evaluations (dynamics) : 2554
Number of crossing function evaluations : 6476
Number of Jacobian-evaluations : 385
Number of model time events : 6
Number of input time events : 0
Number of state events : 12
Number of step events : 0
Minimum integration stepsize : 1.26e-10
Maximum integration stepsize : 105
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Fluid.Examples.PumpingSystem
simulate - Open log
Log-file of program ./dymosim
(generated: Mon Feb 24 23:59:17 2025)
dymosim started
... "Modelica.Fluid.Examples.PumpingSystem" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2000
CPU-time for integration : 0.976 seconds
CPU-time for one grid interval : 0.0976 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 10033
Number of grid points : 10001
Number of accepted steps : 1714
Number of f-evaluations (dynamics) : 3657
Number of crossing function evaluations : 11819
Number of Jacobian-evaluations : 477
Number of model time events : 6
Number of input time events : 0
Number of state events : 12
Number of step events : 0
Minimum integration stepsize : 1.26e-11
Maximum integration stepsize : 124
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Fluid.Examples.PumpingSystem