Check of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut
The model has the same number of unknowns and equations: 149
Check of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut successful.
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225023730 | 20250224233152 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 4.58 | 4.60 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica_org\Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/Modelica\Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut\WorkDir |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.03 s | 1.04 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 3.04 s | 3.05 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 5 | 5 |
| Number NL equation systems | 1 | 1 |
| Largest NL equation system | 1 | 1 |
| MSL410 experiment tolerance | MSL410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.51 s |
| Simulation time | 2.00 s | 2.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 4 | 4 |
| State Events | 4 | 4 |
| Jacobian evaluations | 125 | 134 |
| Integrator Steps | 232 | 241 |
| Total CPU time | 0.01 s | 0.01 s |
| CPU time Integration | 0.01 s | 0.01 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut
The model has the same number of unknowns and equations: 149
Check of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut successful.
check - Open log
Check of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut
The model has the same number of unknowns and equations: 149
Check of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut successful.
translate - Open log
Translation of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut
The DAE has 149 scalar unknowns and 149 scalar equations.
Statistics
Original Model
Number of components: 38
Variables: 324
Constants: 2 (2 scalars)
Parameters: 173 (173 scalars)
Unknowns: 149 (149 scalars)
Differentiated variables: 5 scalars
Equations: 134
Nontrivial: 110
Translated Model
Constants: 29 scalars
Free parameters: 49 scalars
Parameter depending: 101 scalars
Outputs: 7 scalars
Continuous time states: 5 scalars
Time-varying variables: 74 scalars
Alias variables: 71 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {4, 4}
Sizes after manipulation of the linear systems: {0, 0}
Sizes of nonlinear systems of equations: {7}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
heatCapacitor1.T
heatCapacitor2.T
pipe1.T
pipe2.T
pipe3.T
Finished
translate - Open log
Translation of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut
The DAE has 149 scalar unknowns and 149 scalar equations.
Statistics
Original Model
Number of components: 38
Variables: 324
Constants: 2 (2 scalars)
Parameters: 173 (173 scalars)
Unknowns: 149 (149 scalars)
Differentiated variables: 5 scalars
Equations: 134
Nontrivial: 110
Translated Model
Constants: 29 scalars
Free parameters: 49 scalars
Parameter depending: 101 scalars
Outputs: 7 scalars
Continuous time states: 5 scalars
Time-varying variables: 74 scalars
Alias variables: 71 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {4, 4}
Sizes after manipulation of the linear systems: {0, 0}
Sizes of nonlinear systems of equations: {7}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
heatCapacitor1.T
heatCapacitor2.T
pipe1.T
pipe2.T
pipe3.T
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 1
translate - Largest NL equation system
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:04:46 2025)
dymosim started
... "Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2
CPU-time for integration : 0.007 seconds
CPU-time for one grid interval : 0.0035 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 2010
Number of grid points : 2001
Number of accepted steps : 232
Number of f-evaluations (dynamics) : 370
Number of crossing function evaluations : 2274
Number of Jacobian-evaluations : 125
Number of model time events : 4
Number of input time events : 0
Number of state events : 4
Number of step events : 0
Minimum integration stepsize : 1e-06
Maximum integration stepsize : 0.114
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 00:00:00 2025)
dymosim started
... "Modelica.Thermal.FluidHeatFlow.Examples.ParallelPumpDropOut" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2
CPU-time for integration : 0.012 seconds
CPU-time for one grid interval : 0.003 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 4012
Number of grid points : 4001
Number of accepted steps : 241
Number of f-evaluations (dynamics) : 379
Number of crossing function evaluations : 4283
Number of Jacobian-evaluations : 134
Number of model time events : 4
Number of input time events : 0
Number of state events : 4
Number of step events : 0
Minimum integration stepsize : 5e-07
Maximum integration stepsize : 0.114
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)