The model has the same number of unknowns and equations: 21
Check of <a href="Modelica://Modelica.Clocked.Examples.Elementary.RealSignals.UpSample1">Modelica.Clocked.Examples.Elementary.RealSignals.UpSample1</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Clocked/Examples/Elementary/RealSignals/UpSample1 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 0 |
| Number NL equation systems | 0 |
| Largest NL equation system | 0 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 0.09 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 13 |
| State Events | 0 |
| Jacobian evaluations | 263 |
| Integrator Steps | 284 |
| Total CPU time | 0.07 s |
| CPU time Integration | 0.07 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 21
Check of <a href="Modelica://Modelica.Clocked.Examples.Elementary.RealSignals.UpSample1">Modelica.Clocked.Examples.Elementary.RealSignals.UpSample1</a> successful.
translate - Open log
= true
Translation of Modelica.Clocked.Examples.Elementary.RealSignals.UpSample1:
The DAE has 21 scalar unknowns and 21 scalar equations.
Statistics
Original Model
Number of components: 8
Variables: 38
Constants: 1 (8 scalars)
Parameters: 16 (16 scalars)
Unknowns: 18 (18 scalars)
Equations: 15
Nontrivial: 15
Translated Model
Constants: 17 scalars
Free parameters: 7 scalars
Time-varying variables: 16 scalars
Alias variables: 2 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
translate - Continuous time states
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 00:35:49 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "UpSample1.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 0.09
CPU-time for integration : 0.065 seconds
CPU-time for one grid interval : 0.013 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5028
Number of grid points : 5001
Number of accepted steps : 284
Number of f-evaluations (dynamics) : 284
Number of Jacobian-evaluations : 263
Number of model time events : 13
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 6.67e-10
Maximum integration stepsize : 0.00315
Maximum integration order : 1
Calling terminal section