The model has the same number of unknowns and equations: 578
Check of <a href="Modelica://Modelica.Electrical.Polyphase.Examples.TestSensors">Modelica.Electrical.Polyphase.Examples.TestSensors</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Electrical/Polyphase/Examples/TestSensors |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 2 |
| Number NL equation systems | 0 |
| Largest NL equation system | 0 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 0.10 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 0 |
| State Events | 0 |
| Jacobian evaluations | 29 |
| Integrator Steps | 431 |
| Total CPU time | 0.04 s |
| CPU time Integration | 0.04 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 578
Check of <a href="Modelica://Modelica.Electrical.Polyphase.Examples.TestSensors">Modelica.Electrical.Polyphase.Examples.TestSensors</a> successful.
translate - Open log
= true
Translation of Modelica.Electrical.Polyphase.Examples.TestSensors:
The DAE has 578 scalar unknowns and 578 scalar equations.
Statistics
Original Model
Number of components: 82
Variables: 677
Constants: 2 (2 scalars)
Parameters: 133 (155 scalars)
Unknowns: 542 (578 scalars)
Differentiated variables: 3 scalars
Equations: 296
Nontrivial: 237
Translated Model
Constants: 164 scalars
Free parameters: 17 scalars
Parameter depending: 65 scalars
Continuous time states: 2 scalars
Time-varying variables: 60 scalars
Alias variables: 429 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {6}
Sizes after manipulation of the linear systems: {2}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
inductor.inductor[2].i
inductor.inductor[3].i
translate - Continuous time states
- inductor.inductor[2].i
- inductor.inductor[3].i
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 01:09:40 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "TestSensors.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 0.1
CPU-time for integration : 0.036 seconds
CPU-time for one grid interval : 0.018 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 2002
Number of grid points : 2001
Number of accepted steps : 431
Number of f-evaluations (dynamics) : 847
Number of Jacobian-evaluations : 29
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 9.19e-12
Maximum integration stepsize : 0.000365
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)