The model has the same number of unknowns and equations: 151
Check of <a href="Modelica://Modelica.Electrical.QuasiStatic.SinglePhase.Examples.SeriesBode">Modelica.Electrical.QuasiStatic.SinglePhase.Examples.SeriesBode</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Electrical/QuasiStatic/SinglePhase/Examples/SeriesBode |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 1 |
| Number NL equation systems | 0 |
| Largest NL equation system | 0 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 1.00 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 1 |
| State Events | 0 |
| Jacobian evaluations | 20 |
| Integrator Steps | 97 |
| Total CPU time | 0.03 s |
| CPU time Integration | 0.03 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 151
Check of <a href="Modelica://Modelica.Electrical.QuasiStatic.SinglePhase.Examples.SeriesBode">Modelica.Electrical.QuasiStatic.SinglePhase.Examples.SeriesBode</a> successful.
translate - Open log
= true
Translation of Modelica.Electrical.QuasiStatic.SinglePhase.Examples.SeriesBode:
The DAE has 151 scalar unknowns and 151 scalar equations.
Statistics
Original Model
Number of components: 59
Variables: 173
Constants: 1 (1 scalars)
Parameters: 21 (21 scalars)
Unknowns: 151 (151 scalars)
Differentiated variables: 5 scalars
Equations: 110
Nontrivial: 94
Translated Model
Constants: 27 scalars
Free parameters: 10 scalars
Parameter depending: 4 scalars
Outputs: 3 scalars
Continuous time states: 1 scalars
Time-varying variables: 47 scalars
Alias variables: 85 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {6}
Sizes after manipulation of the linear systems: {2}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Initialization problem
Sizes of linear systems of equations: {6}
Sizes after manipulation of the linear systems: {2}
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
inductor.pin_p.reference.gamma
translate - Continuous time states
- inductor.pin_p.reference.gamma
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 01:23:35 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "SeriesBode.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1
CPU-time for integration : 0.033 seconds
CPU-time for one grid interval : 0.0165 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 2002
Number of grid points : 2001
Number of accepted steps : 97
Number of f-evaluations (dynamics) : 186
Number of crossing function evaluations : 2097
Number of Jacobian-evaluations : 20
Number of model time events : 1
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 5e-07
Maximum integration stepsize : 0.0185
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)