The model has the same number of unknowns and equations: 80
Check of <a href="Modelica://Modelica.Electrical.Spice3.Examples.Inverter">Modelica.Electrical.Spice3.Examples.Inverter</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Electrical/Spice3/Examples/Inverter |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 1 |
| Continuous time states | 0 |
| Number NL equation systems | 1 |
| Largest NL equation system | 1 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 0.00 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 14 |
| State Events | 0 |
| Jacobian evaluations | 229 |
| Integrator Steps | 247 |
| Total CPU time | 0.10 s |
| CPU time Integration | 0.10 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 80
Check of <a href="Modelica://Modelica.Electrical.Spice3.Examples.Inverter">Modelica.Electrical.Spice3.Examples.Inverter</a> successful.
translate - Open log
= true
Translation of Modelica.Electrical.Spice3.Examples.Inverter:
The DAE has 80 scalar unknowns and 80 scalar equations.
Statistics
Original Model
Number of components: 22
Variables: 620
Constants: 46 (46 scalars)
Parameters: 494 (494 scalars)
Unknowns: 80 (80 scalars)
Differentiated variables: 2 scalars
Equations: 60
Nontrivial: 53
Translated Model
Constants: 541 scalars
Free parameters: 15 scalars
Parameter depending: 7 scalars
Time-varying variables: 38 scalars
Alias variables: 19 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {21}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 1
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 01:25:13 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "Inverter.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1e-11
CPU-time for integration : 0.098 seconds
CPU-time for one grid interval : 0.0245 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 4007
Number of grid points : 4001
Number of accepted steps : 247
Number of f-evaluations (dynamics) : 247
Number of Jacobian-evaluations : 229
Number of model time events : 14
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 2.5e-18
Maximum integration stepsize : 1.31e-12
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)