The model has the same number of unknowns and equations: 116
Check of <a href="Modelica://Modelica.Mechanics.Translational.Examples.PreLoad">Modelica.Mechanics.Translational.Examples.PreLoad</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Mechanics/Translational/Examples/PreLoad |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 6 |
| Number NL equation systems | 0 |
| Largest NL equation system | 0 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 100.00 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 0 |
| State Events | 7 |
| Jacobian evaluations | 217 |
| Integrator Steps | 708 |
| Total CPU time | 0.04 s |
| CPU time Integration | 0.04 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 116
Check of <a href="Modelica://Modelica.Mechanics.Translational.Examples.PreLoad">Modelica.Mechanics.Translational.Examples.PreLoad</a> successful.
translate - Open log
= true
Translation of Modelica.Mechanics.Translational.Examples.PreLoad:
The DAE has 116 scalar unknowns and 116 scalar equations.
Statistics
Original Model
Number of components: 18
Variables: 171
Parameters: 55 (55 scalars)
Unknowns: 116 (116 scalars)
Differentiated variables: 16 scalars
Equations: 104
Nontrivial: 97
Translated Model
Constants: 21 scalars
Free parameters: 36 scalars
Parameter depending: 2 scalars
Continuous time states: 6 scalars
Time-varying variables: 62 scalars
Alias variables: 50 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
friction.v_rel
innerContactA.s_rel
innerContactB.s_rel
outerContactA.v_rel
outerContactB.s_rel
outerContactB.v_rel
translate - Continuous time states
- friction.v_rel
- innerContactA.s_rel
- innerContactB.s_rel
- outerContactA.v_rel
- outerContactB.s_rel
- outerContactB.v_rel
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 02:10:20 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "PreLoad.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 100
CPU-time for integration : 0.04 seconds
CPU-time for one grid interval : 0.02 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 2016
Number of grid points : 2001
Number of accepted steps : 708
Number of f-evaluations (dynamics) : 1465
Number of crossing function evaluations : 2781
Number of Jacobian-evaluations : 217
Number of model time events : 0
Number of input time events : 0
Number of state events : 7
Number of step events : 0
Minimum integration stepsize : 1.33e-10
Maximum integration stepsize : 2.31
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)