= true
Translation of Modelica.Electrical.Machines.Examples.SynchronousMachines.SMEE_LoadDump:
The DAE has 731 scalar unknowns and 731 scalar equations.
Statistics
Original Model
Number of components: 96
Variables: 1034
Constants: 10 (10 scalars)
Parameters: 372 (440 scalars)
Unknowns: 652 (731 scalars)
Differentiated variables: 31 scalars
Equations: 450
Nontrivial: 364
Translated Model
Constants: 300 scalars
Free parameters: 88 scalars
Parameter depending: 196 scalars
Outputs: 1 scalars
Continuous time states: 8 scalars
Time-varying variables: 139 scalars
Alias variables: 458 scalars
Number of mixed real/discrete systems of equations: 3
Sizes of linear systems of equations: {3}
Sizes after manipulation of the linear systems: {2}
Sizes of nonlinear systems of equations: {45}
Sizes after manipulation of the nonlinear systems: {8}
Number of numerical Jacobians: 0
Initialization problem
Number of mixed real/discrete systems of equations: 3
Sizes of linear systems of equations: {3, 6, 7, 2, 15}
Sizes after manipulation of the linear systems: {0, 2, 2, 2, 5}
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
smee.idq_dr[1]
smee.idq_rr[2]
smee.idq_sr[]
smee.lesigma.i
speed.phi
speed.w
voltageController.I.y