The model has the same number of unknowns and equations: 164
Check of <a href="Modelica://Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2">Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Fluid/Examples/AST_BatchPlant/Test/TankWithEmptyingPipe2 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 2 |
| Number NL equation systems | 2 |
| Largest NL equation system | 1 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 120.00 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 0 |
| State Events | 4 |
| Jacobian evaluations | 87 |
| Integrator Steps | 104 |
| Total CPU time | 0.14 s |
| CPU time Integration | 0.14 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 164
Check of <a href="Modelica://Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2">Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2</a> successful.
translate - Open log
= true
Translation of Modelica.Fluid.Examples.AST_BatchPlant.Test.TankWithEmptyingPipe2:
The DAE has 164 scalar unknowns and 164 scalar equations.
Statistics
Original Model
Number of components: 23
Variables: 332
Parameters: 159 (156 scalars)
Unknowns: 173 (164 scalars)
Differentiated variables: 4 scalars
Equations: 164
Nontrivial: 142
Translated Model
Constants: 107 scalars
Free parameters: 43 scalars
Parameter depending: 68 scalars
Continuous time states: 2 scalars
Time-varying variables: 35 scalars
Alias variables: 67 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {4, 4}
Sizes after manipulation of the nonlinear systems: {1, 1}
Number of numerical Jacobians: 0
Initialization problem
Sizes of linear systems of equations: {2, 2, 2, 2, 2, 2}
Sizes after manipulation of the linear systems: {0, 0, 0, 0, 0, 0}
Sizes of nonlinear systems of equations: {4, 4}
Sizes after manipulation of the nonlinear systems: {1, 1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
tank1.level
tank1.medium.T
translate - Continuous time states
- tank1.level
- tank1.medium.T
translate - Largest NL equation system
- 1
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 02:15:57 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "TankWithEmptyingPipe2.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 120
CPU-time for integration : 0.135 seconds
CPU-time for one grid interval : 0.027 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 5010
Number of grid points : 5001
Number of accepted steps : 104
Number of f-evaluations (dynamics) : 122
Number of crossing function evaluations : 5135
Number of Jacobian-evaluations : 87
Number of model time events : 0
Number of input time events : 0
Number of state events : 4
Number of step events : 0
Minimum integration stepsize : 2.4e-06
Maximum integration stepsize : 20.7
Maximum integration order : 3
Calling terminal section
... "dsfinal.txt" creating (final states)