The model has the same number of unknowns and equations: 307
Check of <a href="Modelica://Modelica.Fluid.Examples.PumpingSystem">Modelica.Fluid.Examples.PumpingSystem</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Fluid/Examples/PumpingSystem |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 2 |
| Continuous time states | 5 |
| Number NL equation systems | 3 |
| Largest NL equation system | 1 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 2000.00 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 6 |
| State Events | 12 |
| Jacobian evaluations | 477 |
| Integrator Steps | 1714 |
| Total CPU time | 1.93 s |
| CPU time Integration | 1.93 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 307
Check of <a href="Modelica://Modelica.Fluid.Examples.PumpingSystem">Modelica.Fluid.Examples.PumpingSystem</a> successful.
translate - Open log
= true
Translation of Modelica.Fluid.Examples.PumpingSystem:
The DAE has 307 scalar unknowns and 307 scalar equations.
Statistics
Original Model
Number of components: 45
Variables: 559
Constants: 61 (61 scalars)
Parameters: 187 (183 scalars)
Unknowns: 311 (307 scalars)
Differentiated variables: 10 scalars
Equations: 229
Nontrivial: 185
Translated Model
Constants: 192 scalars
Free parameters: 56 scalars
Parameter depending: 76 scalars
Continuous time states: 5 scalars
Time-varying variables: 91 scalars
Alias variables: 136 scalars
Number of mixed real/discrete systems of equations: 4
Sizes of linear systems of equations: {3, 7}
Sizes after manipulation of the linear systems: {2, 2}
Sizes of nonlinear systems of equations: {2, 7, 3}
Sizes after manipulation of the nonlinear systems: {1, 1, 1}
Number of numerical Jacobians: 2
Initialization problem
Number of mixed real/discrete systems of equations: 2
Sizes of linear systems of equations: {2, 2}
Sizes after manipulation of the linear systems: {0, 0}
Sizes of nonlinear systems of equations: {2, 7}
Sizes after manipulation of the nonlinear systems: {1, 1}
Number of numerical Jacobians: 2
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
PT1.y
pumps.medium.p
pumps.medium.T
reservoir.level
reservoir.medium.T
translate - Continuous time states
- PT1.y
- pumps.medium.p
- pumps.medium.T
- reservoir.level
- reservoir.medium.T
translate - Largest NL equation system
- 1
- 1
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 02:11:30 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "PumpingSystem.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2000
CPU-time for integration : 1.93 seconds
CPU-time for one grid interval : 0.193 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 10035
Number of grid points : 10001
Number of accepted steps : 1714
Number of f-evaluations (dynamics) : 3657
Number of crossing function evaluations : 11822
Number of Jacobian-evaluations : 477
Number of model time events : 6
Number of input time events : 0
Number of state events : 12
Number of step events : 0
Minimum integration stepsize : 1.26e-11
Maximum integration stepsize : 124
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)