The model has the same number of unknowns and equations: 67
Check of <a href="Modelica://Modelica.Magnetic.FluxTubes.Examples.BasicExamples.SaturatedInductor">Modelica.Magnetic.FluxTubes.Examples.BasicExamples.SaturatedInductor</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Magnetic/FluxTubes/Examples/BasicExamples/SaturatedInductor |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 1 |
| Number NL equation systems | 1 |
| Largest NL equation system | 3 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 0.10 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 0 |
| State Events | 0 |
| Jacobian evaluations | 300 |
| Integrator Steps | 3821 |
| Total CPU time | 0.14 s |
| CPU time Integration | 0.14 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 67
Check of <a href="Modelica://Modelica.Magnetic.FluxTubes.Examples.BasicExamples.SaturatedInductor">Modelica.Magnetic.FluxTubes.Examples.BasicExamples.SaturatedInductor</a> successful.
translate - Open log
= true
Translation of Modelica.Magnetic.FluxTubes.Examples.BasicExamples.SaturatedInductor:
The DAE has 67 scalar unknowns and 67 scalar equations.
Statistics
Original Model
Number of components: 12
Variables: 104
Parameters: 37 (37 scalars)
Unknowns: 67 (67 scalars)
Differentiated variables: 2 scalars
Equations: 62
Nontrivial: 51
Translated Model
Constants: 12 scalars
Free parameters: 28 scalars
Parameter depending: 11 scalars
Continuous time states: 1 scalars
Time-varying variables: 23 scalars
Alias variables: 30 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {10}
Sizes after manipulation of the linear systems: {0}
Sizes of nonlinear systems of equations: {12}
Sizes after manipulation of the nonlinear systems: {3}
Number of numerical Jacobians: 0
Initialization problem
Sizes of nonlinear systems of equations: {8}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Dynamically selected continuous time states
There is one set of dynamic state selection.
There is one state to be selected from:
coil.i
coil.Phi
r_mLeak.port_p.Phi
translate - Continuous time states
translate - Largest NL equation system
- 3
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 01:33:38 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "SaturatedInductor.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 0.1
CPU-time for integration : 0.138 seconds
CPU-time for one grid interval : 0.0276 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 3821
Number of f-evaluations (dynamics) : 7956
Number of Jacobian-evaluations : 300
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1.84e-11
Maximum integration stepsize : 8.14e-05
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)