The model has the same number of unknowns and equations: 127
Check of <a href="Modelica://Modelica.Thermal.FluidHeatFlow.Examples.WaterPump">Modelica.Thermal.FluidHeatFlow.Examples.WaterPump</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Thermal/FluidHeatFlow/Examples/WaterPump |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 1 |
| Number NL equation systems | 1 |
| Largest NL equation system | 2 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 2.00 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 4 |
| State Events | 4 |
| Jacobian evaluations | 183 |
| Integrator Steps | 196 |
| Total CPU time | 0.09 s |
| CPU time Integration | 0.08 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 127
Check of <a href="Modelica://Modelica.Thermal.FluidHeatFlow.Examples.WaterPump">Modelica.Thermal.FluidHeatFlow.Examples.WaterPump</a> successful.
translate - Open log
= true
Translation of Modelica.Thermal.FluidHeatFlow.Examples.WaterPump:
The DAE has 127 scalar unknowns and 127 scalar equations.
Statistics
Original Model
Number of components: 30
Variables: 283
Constants: 4 (4 scalars)
Parameters: 152 (152 scalars)
Unknowns: 127 (127 scalars)
Differentiated variables: 3 scalars
Equations: 106
Nontrivial: 87
Translated Model
Constants: 36 scalars
Free parameters: 66 scalars
Parameter depending: 64 scalars
Outputs: 5 scalars
Continuous time states: 1 scalars
Time-varying variables: 51 scalars
Alias variables: 66 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {5}
Sizes after manipulation of the linear systems: {2}
Sizes of nonlinear systems of equations: {9}
Sizes after manipulation of the nonlinear systems: {2}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
speed.phi
translate - Continuous time states
- speed.phi
translate - Largest NL equation system
- 2
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 02:26:13 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "WaterPump.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2
CPU-time for integration : 0.084 seconds
CPU-time for one grid interval : 0.021 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 4012
Number of grid points : 4001
Number of accepted steps : 196
Number of f-evaluations (dynamics) : 197
Number of crossing function evaluations : 4227
Number of Jacobian-evaluations : 183
Number of model time events : 4
Number of input time events : 0
Number of state events : 4
Number of step events : 0
Minimum integration stepsize : 9.42e-09
Maximum integration stepsize : 0.262
Maximum integration order : 2
Calling terminal section
... "dsfinal.txt" creating (final states)