The model has the same number of unknowns and equations: 50
Check of <a href="Modelica://Modelica.Thermal.FluidHeatFlow.Examples.TwoTanks">Modelica.Thermal.FluidHeatFlow.Examples.TwoTanks</a> successful.
| MAP LIB Reference Results | |
|---|---|
| Testrun ID | MAP-LIB_ReferenceResults |
| Simulator | Dymola |
| Status | PASS |
| Run time | N/A |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Thermal/FluidHeatFlow/Examples/TwoTanks |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Warnings | None |
| Errors | None |
| Open log  | |
| Numerical Jacobians | 0 |
| Continuous time states | 4 |
| Number NL equation systems | 1 |
| Largest NL equation system | 1 |
| MAP LIB Reference Results | |
|---|---|
| Status | PASS |
| Task runtime | N/A |
| Simulation time | 1.50 s |
| Copy result file path  | |
| Open log  | |
| Time Events | 0 |
| State Events | 0 |
| Jacobian evaluations | 21 |
| Integrator Steps | 75 |
| Total CPU time | 0.12 s |
| CPU time Integration | 0.12 s |
| CPU time Initialization | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 50
Check of <a href="Modelica://Modelica.Thermal.FluidHeatFlow.Examples.TwoTanks">Modelica.Thermal.FluidHeatFlow.Examples.TwoTanks</a> successful.
translate - Open log
= true
Translation of Modelica.Thermal.FluidHeatFlow.Examples.TwoTanks:
The DAE has 50 scalar unknowns and 50 scalar equations.
Statistics
Original Model
Number of components: 11
Variables: 115
Constants: 2 (2 scalars)
Parameters: 63 (63 scalars)
Unknowns: 50 (50 scalars)
Differentiated variables: 4 scalars
Equations: 48
Nontrivial: 40
Translated Model
Constants: 13 scalars
Free parameters: 33 scalars
Parameter depending: 22 scalars
Outputs: 5 scalars
Continuous time states: 4 scalars
Time-varying variables: 30 scalars
Alias variables: 17 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {3}
Sizes after manipulation of the linear systems: {0}
Sizes of nonlinear systems of equations: {1}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
openTank1.H
openTank1.m
openTank2.H
openTank2.m
translate - Continuous time states
- openTank1.H
- openTank1.m
- openTank2.H
- openTank2.m
translate - Largest NL equation system
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 02:26:30 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "TwoTanks.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1.5
CPU-time for integration : 0.121 seconds
CPU-time for one grid interval : 0.0242 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 75
Number of f-evaluations (dynamics) : 139
Number of crossing function evaluations : 5075
Number of Jacobian-evaluations : 21
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 5.99e-08
Maximum integration stepsize : 0.0537
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)