The model has the same number of unknowns and equations: 250
Check of <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase">Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase</a> successful.
| MAP LIB Reference Results | Modelica.Electrical.Machines from #4789 | ||
|---|---|---|---|
| Testrun ID | MAP-LIB_ReferenceResults | 20260528110734 | |
| Simulator | Dymola | Dymola | |
| Status | PASS | PASS | |
| Run time | N/A | 4.04 | |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Electrical/Machines/Examples/DCMachines/DCSE_SinglePhase | D:/MSL_Nightly/Tests/Output/Testruns/Dymola/20260528110734/Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase\WorkDir | |
| Differences in Simulation Settings | |||
| N Intervals | 40000 | 20000 | |
| Tolerance | 1e-07 | 1e-06 | |
| MAP LIB Reference Results | Modelica.Electrical.Machines from #4789 | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | N/A | 0.50 s |
| Warnings | None | 0 |
| Errors | None | 0 |
| Open log  | Open log  |
| MAP LIB Reference Results | Modelica.Electrical.Machines from #4789 | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | N/A | 3.00 s |
| Warnings | None | 0 |
| Errors | None | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 3 | 3 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| Modifier | 0 | 0 |
| MAP LIB Reference Results | Modelica.Electrical.Machines from #4789 | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | N/A | 0.50 s |
| Simulation time | 2.00 s | 2.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 2 | 2 |
| State Events | 0 | 0 |
| Jacobian evaluations | 291 | 181 |
| Integrator Steps | 8589 | 6000 |
| Total CPU time | 0.56 s | 0.04 s |
| CPU time Integration | 0.56 s | 0.04 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 250
Check of <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase">Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase</a> successful.
check - Open log
Check of <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase">Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase</a>
The model has the same number of unknowns and equations: 250
Check of <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase">Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase</a> successful.
translate - Open log
= true
Translation of Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase:
The DAE has 250 scalar unknowns and 250 scalar equations.
Statistics
Original Model
Number of components: 47
Variables: 424
Constants: 3 (3 scalars)
Parameters: 171 (171 scalars)
Unknowns: 250 (250 scalars)
Differentiated variables: 14 scalars
Equations: 211
Nontrivial: 155
Translated Model
Constants: 128 scalars
Free parameters: 32 scalars
Parameter depending: 97 scalars
Continuous time states: 3 scalars
Time-varying variables: 36 scalars
Alias variables: 131 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {3, 2}
Sizes after manipulation of the linear systems: {0, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
dcse.la.i
loadInertia.phi
loadInertia.w
translate - Open log
Translation of <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase">Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase</a>
The DAE has 250 scalar unknowns and 250 scalar equations.
Statistics
Original Model
Number of components: 47
Variables: 425
Constants: 3 (3 scalars)
Parameters: 172 (172 scalars)
Unknowns: 250 (250 scalars)
Differentiated variables: 14 scalars
Equations: 211
Nontrivial: 155
Translated Model
Constants: 129 scalars
Free parameters: 32 scalars
Parameter depending: 97 scalars
Continuous time states: 3 scalars
Time-varying variables: 36 scalars
Alias variables: 131 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {3, 2}
Sizes after manipulation of the linear systems: {0, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
<a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase#text$dcse.la:i">dcse.la.i</a>
<a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase#text$loadInertia:phi">loadInertia.phi</a>
<a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase#text$loadInertia:w">loadInertia.w</a>
Finished
translate - Continuous time states
- dcse.la.i
- loadInertia.phi
- loadInertia.w
translate - Continuous time states
- <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase#text$dcse.la:i">dcse.la.i</a>
- <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase#text$loadInertia:phi">loadInertia.phi</a>
- <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase#text$loadInertia:w">loadInertia.w</a>
translate - Largest NL equation system
translate - Largest NL equation system
translate - Modifier
translate - Modifier
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 01:05:34 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "DCSE_SinglePhase.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2
CPU-time for integration : 0.56 seconds
CPU-time for one grid interval : 0.014 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 40002
Number of grid points : 40001
Number of accepted steps : 8589
Number of f-evaluations (dynamics) : 17492
Number of crossing function evaluations : 48589
Number of Jacobian-evaluations : 291
Number of model time events : 2
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1.54e-10
Maximum integration stepsize : 0.000421
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
simulate - Open log
Log-file of program ./dymosim
(generated: Thu May 28 11:08:40 2026)
dymosim started
... "Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 2
CPU-time for integration : 0.039 seconds
CPU-time for one grid interval : 0.00195 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 20002
Number of grid points : 20001
Number of accepted steps : 6000
Number of f-evaluations (dynamics) : 12140
Number of crossing function evaluations : 26000
Number of Jacobian-evaluations : 181
Number of model time events : 2
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1.54e-09
Maximum integration stepsize : 0.000651
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of Modelica.Electrical.Machines.Examples.DCMachines.DCSE_SinglePhase