214 – Modelica.Electrical.Machines.Examples.InductionMachines.IMC_Inverter

Testcase report

MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Testrun ID MAP-LIB_ReferenceResults 20260528110734
Simulator Dymola Dymola
Status PASS PASS
Run time N/A 4.51
Workdir D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Electrical/Machines/Examples/InductionMachines/IMC_Inverter D:/MSL_Nightly/Tests/Output/Testruns/Dymola/20260528110734/Modelica.Electrical.Machines.Examples.InductionMachines.IMC_Inverter\WorkDir
Differences in Simulation Settings
N Intervals 30000 15000
Tolerance 1e-07 1e-06
check
 
MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Status PASS PASS
Task runtime N/A 1.00 s
Warnings None 0
Errors None 0
Open log  Open log 
translate
 
MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Status PASS PASS
Task runtime N/A 3.01 s
Warnings None 0
Errors None 0
Open log  Open log 
Numerical Jacobians 0 0
Continuous time states 7 7
Number NL equation systems 0 0
Largest NL equation system 0 0
Modifier 0 0
simulate
 
MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Status PASS PASS
Task runtime N/A 0.50 s
Simulation time 1.50 s 1.50 s
Copy result file path  Copy result file path 
Open log  Open log 
Time Events 2 2
State Events 0 0
Jacobian evaluations 65 55
Integrator Steps 1424 1001
Total CPU time 0.61 s 0.08 s
CPU time Integration 0.61 s 0.07 s
CPU time Initialization 0.00 s 0.00 s