215 – Modelica.Electrical.Machines.Examples.InductionMachines.IMC_InverterDrive

Testcase report

MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Testrun ID MAP-LIB_ReferenceResults 20260528110734
Simulator Dymola Dymola
Status PASS PASS
Run time N/A 21.53
Workdir D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Electrical/Machines/Examples/InductionMachines/IMC_InverterDrive D:/MSL_Nightly/Tests/Output/Testruns/Dymola/20260528110734/Modelica.Electrical.Machines.Examples.InductionMachines.IMC_InverterDrive\WorkDir
Differences in Simulation Settings
N Intervals 60000 30000
Tolerance 1e-07 1e-06
check
 
MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Status PASS PASS
Task runtime N/A 1.50 s
Warnings None 0
Errors None 0
Open log  Open log 
translate
 
MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Status PASS PASS
Task runtime N/A 3.00 s
Warnings None 0
Errors None 0
Open log  Open log 
Numerical Jacobians 0 0
Continuous time states 11 11
Number NL equation systems 0 0
Largest NL equation system 0 0
Modifier 0 0
simulate
 
MAP LIB Reference Results Modelica.Electrical.Machines from #4789
Status PASS PASS
Task runtime N/A 17.02 s
Simulation time 1.50 s 1.50 s
Copy result file path  Copy result file path 
Open log  Open log 
Time Events 20903 20980
State Events 1474 1469
Jacobian evaluations 379313 313902
Integrator Steps 539637 426003
Total CPU time 23.00 s 16.40 s
CPU time Integration 23.00 s 16.40 s
CPU time Initialization 0.00 s 0.00 s