The model has the same number of unknowns and equations: 272
Check of <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCPM_Cooling">Modelica.Electrical.Machines.Examples.DCMachines.DCPM_Cooling</a> successful.
| MAP LIB Reference Results | ModelicaTest.Electrical.Machines from #4788 | ||
|---|---|---|---|
| Testrun ID | MAP-LIB_ReferenceResults | 20260528114214 | |
| Simulator | Dymola | Dymola | |
| Status | PASS | PASS | |
| Run time | N/A | 3.54 | |
| Workdir | D:/MSL_Nightly/Repos/MAP-LIB_ReferenceResults/Modelica/Electrical/Machines/Examples/DCMachines/DCPM_Cooling | D:/MSL_Nightly/Tests/Output/Testruns/Dymola/20260528114214/ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling\WorkDir | |
| Differences in Simulation Settings | |||
| T Stop | 25 | 5.75 | |
| Tolerance | 1e-07 | 1e-06 | |
| N Intervals | 500000 | 5750 | |
| MAP LIB Reference Results | ModelicaTest.Electrical.Machines from #4788 | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | N/A | 0.51 s |
| Warnings | None | 0 |
| Errors | None | 0 |
| Open log  | Open log  |
| MAP LIB Reference Results | ModelicaTest.Electrical.Machines from #4788 | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | N/A | 2.50 s |
| Warnings | None | 0 |
| Errors | None | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 5 | 5 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| MAP LIB Reference Results | ModelicaTest.Electrical.Machines from #4788 | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | N/A | 0.50 s |
| Simulation time | 25.00 s | 5.75 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 25 | 11 |
| State Events | 24 | 0 |
| Jacobian evaluations | 979 | 184 |
| Integrator Steps | 8840 | 1529 |
| Total CPU time | 7.19 s | 0.01 s |
| CPU time Integration | 7.19 s | 0.01 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
The model has the same number of unknowns and equations: 272
Check of <a href="Modelica://Modelica.Electrical.Machines.Examples.DCMachines.DCPM_Cooling">Modelica.Electrical.Machines.Examples.DCMachines.DCPM_Cooling</a> successful.
check - Open log
Check of <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling">ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling</a>
The model has the same number of unknowns and equations: 272
Check of <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling">ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling</a> successful.
translate - Open log
= true
Translation of Modelica.Electrical.Machines.Examples.DCMachines.DCPM_Cooling:
The DAE has 272 scalar unknowns and 272 scalar equations.
Statistics
Original Model
Number of components: 52
Variables: 501
Constants: 6 (6 scalars)
Parameters: 223 (223 scalars)
Unknowns: 272 (272 scalars)
Differentiated variables: 15 scalars
Equations: 218
Nontrivial: 170
Translated Model
Constants: 128 scalars
Free parameters: 56 scalars
Parameter depending: 129 scalars
Continuous time states: 5 scalars
Time-varying variables: 48 scalars
Alias variables: 140 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {2, 13}
Sizes after manipulation of the linear systems: {0, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
armature.T
core.T
dcpm.la.i
loadInertia.phi
loadInertia.w
translate - Open log
Translation of <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling">ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling</a>
The DAE has 272 scalar unknowns and 272 scalar equations.
Statistics
Original Model
Number of components: 52
Variables: 501
Constants: 6 (6 scalars)
Parameters: 223 (223 scalars)
Unknowns: 272 (272 scalars)
Differentiated variables: 15 scalars
Equations: 218
Nontrivial: 170
Translated Model
Constants: 128 scalars
Free parameters: 56 scalars
Parameter depending: 129 scalars
Continuous time states: 5 scalars
Time-varying variables: 48 scalars
Alias variables: 140 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {13, 2}
Sizes after manipulation of the linear systems: {0, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
<a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$armature:T">armature.T</a>
<a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$core:T">core.T</a>
<a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$dcpm.la:i">dcpm.la.i</a>
<a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$loadInertia:phi">loadInertia.phi</a>
<a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$loadInertia:w">loadInertia.w</a>
Finished
translate - Continuous time states
- armature.T
- core.T
- dcpm.la.i
- loadInertia.phi
- loadInertia.w
translate - Continuous time states
- <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$armature:T">armature.T</a>
- <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$core:T">core.T</a>
- <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$dcpm.la:i">dcpm.la.i</a>
- <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$loadInertia:phi">loadInertia.phi</a>
- <a href="Modelica://ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling#text$loadInertia:w">loadInertia.w</a>
translate - Largest NL equation system
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue May 5 01:06:01 2020)
dymosim started
... "dsin.txt" loading (dymosim input file)
... "DCPM_Cooling.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 25
CPU-time for integration : 7.19 seconds
CPU-time for one grid interval : 0.0144 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 500099
Number of grid points : 500001
Number of accepted steps : 8840
Number of f-evaluations (dynamics) : 17693
Number of crossing function evaluations : 508921
Number of Jacobian-evaluations : 979
Number of model time events : 25
Number of input time events : 0
Number of state events : 24
Number of step events : 0
Minimum integration stepsize : 7.12e-10
Maximum integration stepsize : 0.0151
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
simulate - Open log
Log-file of program ./dymosim
(generated: Thu May 28 11:42:49 2026)
dymosim started
... "ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 5.75
CPU-time for integration : 0.013 seconds
CPU-time for one grid interval : 0.00226 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5763
Number of grid points : 5751
Number of accepted steps : 1529
Number of f-evaluations (dynamics) : 3031
Number of crossing function evaluations : 7279
Number of Jacobian-evaluations : 184
Number of model time events : 11
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 7.12e-09
Maximum integration stepsize : 0.0206
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Electrical.Machines.Examples.DCMachines.DCPM_Cooling