Check of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal
The model has the same number of unknowns and equations: 173
Check of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 6.11 | 5.65 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.54 s | 1.53 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 4.05 s | 3.58 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 0 | 0 |
| Number NL equation systems | 1 | 1 |
| Largest NL equation system | 5 | 5 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.52 s |
| Simulation time | 1.01 s | 1.01 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 1 | 1 |
| State Events | 6 | 6 |
| Jacobian evaluations | 106 | 106 |
| Integrator Steps | 116 | 116 |
| Total CPU time | 0.24 s | 0.24 s |
| CPU time Integration | 0.24 s | 0.24 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal
The model has the same number of unknowns and equations: 173
Check of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal successful.
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal
The model has the same number of unknowns and equations: 173
Check of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal successful.
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal
The DAE has 173 scalar unknowns and 173 scalar equations.
Statistics
Original Model
Number of components: 27
Variables: 385
Constants: 20 (48 scalars)
Parameters: 180 (177 scalars)
Unknowns: 185 (173 scalars)
Equations: 181
Nontrivial: 163
Translated Model
Constants: 149 scalars
Free parameters: 42 scalars
Parameter depending: 88 scalars
Time-varying variables: 50 scalars
Alias variables: 69 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {31}
Sizes after manipulation of the nonlinear systems: {5}
Number of numerical Jacobians: 0
Initialization problem
Sizes of nonlinear systems of equations: {31}
Sizes after manipulation of the nonlinear systems: {3}
Sizes of simplified homotopy nonlinear systems of equations: {25}
Sizes after manipulation of the simplified homotopy nonlinear systems: {3}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Finished
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal
The DAE has 173 scalar unknowns and 173 scalar equations.
Statistics
Original Model
Number of components: 27
Variables: 385
Constants: 20 (48 scalars)
Parameters: 180 (177 scalars)
Unknowns: 185 (173 scalars)
Equations: 181
Nontrivial: 163
Translated Model
Constants: 149 scalars
Free parameters: 42 scalars
Parameter depending: 88 scalars
Time-varying variables: 50 scalars
Alias variables: 69 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {31}
Sizes after manipulation of the nonlinear systems: {5}
Number of numerical Jacobians: 0
Initialization problem
Sizes of nonlinear systems of equations: {31}
Sizes after manipulation of the nonlinear systems: {3}
Sizes of simplified homotopy nonlinear systems of equations: {25}
Sizes after manipulation of the simplified homotopy nonlinear systems: {3}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 5
translate - Largest NL equation system
- 5
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:48:58 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.503586
Tag: simulation.nonlinear[1]
For debugging information enable
Simulation/Setup/Debug/Nonlinear solver diagnostics/Detailed logging of failed nonlinear solutions.
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.503691747
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.503788
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.5038999691845377
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.50399
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.5040861622947022
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.5040543464013985
Tag: simulation.nonlinear[1]
Integration terminated successfully at T = 1.01
CPU-time for integration : 0.243 seconds
CPU-time for one grid interval : 0.0486 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5016
Number of grid points : 5001
Number of accepted steps : 116
Number of f-evaluations (dynamics) : 116
Number of crossing function evaluations : 5130
Number of Jacobian-evaluations : 106
Number of model time events : 1
Number of input time events : 0
Number of state events : 6
Number of step events : 0
Minimum integration stepsize : 3.11e-08
Maximum integration stepsize : 0.424
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:02:33 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.503586
Tag: simulation.nonlinear[1]
For debugging information enable
Simulation/Setup/Debug/Nonlinear solver diagnostics/Detailed logging of failed nonlinear solutions.
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.503691747
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.503788
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.5038999691845377
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.50399
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.5040861622947022
Tag: simulation.nonlinear[1]
Warning: Failed to solve nonlinear system using Newton solver.
Time: 0.5040543464013985
Tag: simulation.nonlinear[1]
Integration terminated successfully at T = 1.01
CPU-time for integration : 0.244 seconds
CPU-time for one grid interval : 0.0488 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5016
Number of grid points : 5001
Number of accepted steps : 116
Number of f-evaluations (dynamics) : 116
Number of crossing function evaluations : 5130
Number of Jacobian-evaluations : 106
Number of model time events : 1
Number of input time events : 0
Number of state events : 6
Number of step events : 0
Minimum integration stepsize : 3.11e-08
Maximum integration stepsize : 0.424
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Fittings.TestJunctionIdeal