Check of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve
The model has the same number of unknowns and equations: 142
Check of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 4.63 | 5.64 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.02 s | 1.54 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 3.06 s | 3.55 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 1 | 1 |
| Continuous time states | 2 | 2 |
| Number NL equation systems | 1 | 1 |
| Largest NL equation system | 1 | 1 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.50 s | 0.50 s |
| Simulation time | 3.00 s | 3.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 2 | 2 |
| State Events | 1 | 1 |
| Jacobian evaluations | 90 | 90 |
| Integrator Steps | 135 | 135 |
| Total CPU time | 0.13 s | 0.12 s |
| CPU time Integration | 0.12 s | 0.12 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve
The model has the same number of unknowns and equations: 142
Check of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve successful.
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve
The model has the same number of unknowns and equations: 142
Check of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve successful.
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve
The DAE has 142 scalar unknowns and 142 scalar equations.
Statistics
Original Model
Number of components: 27
Variables: 334
Constants: 62 (62 scalars)
Parameters: 107 (104 scalars)
Unknowns: 165 (142 scalars)
Differentiated variables: 4 scalars
Equations: 145
Nontrivial: 113
Translated Model
Constants: 131 scalars
Free parameters: 32 scalars
Parameter depending: 44 scalars
Continuous time states: 2 scalars
Time-varying variables: 30 scalars
Alias variables: 71 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {2}
Sizes after manipulation of the linear systems: {0}
Sizes of nonlinear systems of equations: {2}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 1
Initialization problem
Number of mixed real/discrete systems of equations: 1
Sizes of nonlinear systems of equations: {13}
Sizes after manipulation of the nonlinear systems: {3}
Sizes of simplified homotopy nonlinear systems of equations: {12}
Sizes after manipulation of the simplified homotopy nonlinear systems: {3}
Number of numerical Jacobians: 2
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
pump.medium.h
pump.medium.p
Finished
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve
The DAE has 142 scalar unknowns and 142 scalar equations.
Statistics
Original Model
Number of components: 27
Variables: 334
Constants: 62 (62 scalars)
Parameters: 107 (104 scalars)
Unknowns: 165 (142 scalars)
Differentiated variables: 4 scalars
Equations: 145
Nontrivial: 113
Translated Model
Constants: 131 scalars
Free parameters: 32 scalars
Parameter depending: 44 scalars
Continuous time states: 2 scalars
Time-varying variables: 30 scalars
Alias variables: 71 scalars
Number of mixed real/discrete systems of equations: 1
Sizes of linear systems of equations: {2}
Sizes after manipulation of the linear systems: {0}
Sizes of nonlinear systems of equations: {2}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 1
Initialization problem
Number of mixed real/discrete systems of equations: 1
Sizes of nonlinear systems of equations: {13}
Sizes after manipulation of the nonlinear systems: {3}
Sizes of simplified homotopy nonlinear systems of equations: {12}
Sizes after manipulation of the simplified homotopy nonlinear systems: {3}
Number of numerical Jacobians: 2
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
pump.medium.h
pump.medium.p
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 1
translate - Largest NL equation system
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:49:11 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 3
CPU-time for integration : 0.125 seconds
CPU-time for one grid interval : 0.025 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5006
Number of grid points : 5001
Number of accepted steps : 135
Number of f-evaluations (dynamics) : 238
Number of crossing function evaluations : 5145
Number of Jacobian-evaluations : 90
Number of model time events : 2
Number of input time events : 0
Number of state events : 1
Number of step events : 0
Minimum integration stepsize : 1.8e-08
Maximum integration stepsize : 0.419
Maximum integration order : 3
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:02:47 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 3
CPU-time for integration : 0.124 seconds
CPU-time for one grid interval : 0.0248 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 5006
Number of grid points : 5001
Number of accepted steps : 135
Number of f-evaluations (dynamics) : 238
Number of crossing function evaluations : 5145
Number of Jacobian-evaluations : 90
Number of model time events : 2
Number of input time events : 0
Number of state events : 1
Number of step events : 0
Minimum integration stepsize : 1.8e-08
Maximum integration stepsize : 0.419
Maximum integration order : 3
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve