Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes
The model has the same number of unknowns and equations: 206
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 4.63 | 4.64 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.00 s | 1.01 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 3.04 s | 3.05 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 2 | 2 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.51 s |
| Simulation time | 10.00 s | 10.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 0 | 0 |
| State Events | 0 | 0 |
| Jacobian evaluations | 16 | 16 |
| Integrator Steps | 64 | 64 |
| Total CPU time | 0.01 s | 0.01 s |
| CPU time Integration | 0.01 s | 0.01 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes
The model has the same number of unknowns and equations: 206
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes successful.
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes
The model has the same number of unknowns and equations: 206
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes successful.
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes
The DAE has 206 scalar unknowns and 206 scalar equations.
Statistics
Original Model
Number of components: 22
Variables: 287
Constants: 2 (2 scalars)
Parameters: 93 (89 scalars)
Unknowns: 192 (206 scalars)
Differentiated variables: 6 scalars
Equations: 167
Nontrivial: 130
Translated Model
Constants: 169 scalars
Free parameters: 21 scalars
Parameter depending: 37 scalars
Continuous time states: 2 scalars
Time-varying variables: 16 scalars
Alias variables: 54 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
mixingVolume1.medium.T
mixingVolume2.medium.T
Finished
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes
The DAE has 206 scalar unknowns and 206 scalar equations.
Statistics
Original Model
Number of components: 22
Variables: 287
Constants: 2 (2 scalars)
Parameters: 93 (89 scalars)
Unknowns: 192 (206 scalars)
Differentiated variables: 6 scalars
Equations: 167
Nontrivial: 130
Translated Model
Constants: 169 scalars
Free parameters: 21 scalars
Parameter depending: 37 scalars
Continuous time states: 2 scalars
Time-varying variables: 16 scalars
Alias variables: 54 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
mixingVolume1.medium.T
mixingVolume2.medium.T
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:49:41 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 10
CPU-time for integration : 0.007 seconds
CPU-time for one grid interval : 0.0014 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 64
Number of f-evaluations (dynamics) : 116
Number of crossing function evaluations : 5064
Number of Jacobian-evaluations : 16
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 2e-06
Maximum integration stepsize : 0.382
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:03:16 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 10
CPU-time for integration : 0.007 seconds
CPU-time for one grid interval : 0.0014 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 64
Number of f-evaluations (dynamics) : 116
Number of crossing function evaluations : 5064
Number of Jacobian-evaluations : 16
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 2e-06
Maximum integration stepsize : 0.382
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumes