Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates
The model has the same number of unknowns and equations: 256
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 4.68 | 5.18 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.04 s | 1.03 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 3.06 s | 3.56 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 1 | 1 |
| Continuous time states | 3 | 3 |
| Number NL equation systems | 2 | 2 |
| Largest NL equation system | 3 | 3 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.52 s | 0.51 s |
| Simulation time | 10.00 s | 10.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 0 | 0 |
| State Events | 0 | 0 |
| Jacobian evaluations | 17 | 17 |
| Integrator Steps | 67 | 67 |
| Total CPU time | 0.34 s | 0.34 s |
| CPU time Integration | 0.34 s | 0.34 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates
The model has the same number of unknowns and equations: 256
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates successful.
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates
The model has the same number of unknowns and equations: 256
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates successful.
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates
The DAE has 256 scalar unknowns and 256 scalar equations.
Statistics
Original Model
Number of components: 34
Variables: 473
Constants: 58 (58 scalars)
Parameters: 139 (135 scalars)
Unknowns: 276 (262 scalars)
Differentiated variables: 8 scalars
Equations: 223
Nontrivial: 184
Translated Model
Constants: 210 scalars
Free parameters: 29 scalars
Parameter depending: 54 scalars
Continuous time states: 3 scalars
Time-varying variables: 62 scalars
Alias variables: 100 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {14, 5}
Sizes after manipulation of the nonlinear systems: {3, 1}
Number of numerical Jacobians: 1
Initialization problem
Number of mixed real/discrete systems of equations: 1
Sizes of nonlinear systems of equations: {19}
Sizes after manipulation of the nonlinear systems: {3}
Number of numerical Jacobians: 1
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
mixingVolume1.medium.h
mixingVolume1.medium.p
mixingVolume2.medium.h
Warning: Some variables are iteration variables of the initialization problem:
but they are not given any explicit start values. Zero will be used.
Iteration variables:
der(mixingVolume2.medium.h)
Finished
Warning: WARNINGS have been issued.
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates
The DAE has 256 scalar unknowns and 256 scalar equations.
Statistics
Original Model
Number of components: 34
Variables: 473
Constants: 58 (58 scalars)
Parameters: 139 (135 scalars)
Unknowns: 276 (262 scalars)
Differentiated variables: 8 scalars
Equations: 223
Nontrivial: 184
Translated Model
Constants: 210 scalars
Free parameters: 29 scalars
Parameter depending: 54 scalars
Continuous time states: 3 scalars
Time-varying variables: 62 scalars
Alias variables: 100 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {14, 5}
Sizes after manipulation of the nonlinear systems: {3, 1}
Number of numerical Jacobians: 1
Initialization problem
Number of mixed real/discrete systems of equations: 1
Sizes of nonlinear systems of equations: {19}
Sizes after manipulation of the nonlinear systems: {3}
Number of numerical Jacobians: 1
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
mixingVolume1.medium.h
mixingVolume1.medium.p
mixingVolume2.medium.h
Warning: Some variables are iteration variables of the initialization problem:
but they are not given any explicit start values. Zero will be used.
Iteration variables:
der(mixingVolume2.medium.h)
Finished
Warning: WARNINGS have been issued.
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 3
- 1
translate - Largest NL equation system
- 3
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:49:42 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 10
CPU-time for integration : 0.338 seconds
CPU-time for one grid interval : 0.0676 milliseconds
CPU-time for initialization : 0.002 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 67
Number of f-evaluations (dynamics) : 125
Number of crossing function evaluations : 5067
Number of Jacobian-evaluations : 17
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 2e-06
Maximum integration stepsize : 0.419
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:03:18 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 10
CPU-time for integration : 0.344 seconds
CPU-time for one grid interval : 0.0688 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 67
Number of f-evaluations (dynamics) : 125
Number of crossing function evaluations : 5067
Number of Jacobian-evaluations : 17
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 2e-06
Maximum integration stepsize : 0.419
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestComponents.Vessels.TestMixingVolumesPressureStates