Check of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank
The model has the same number of unknowns and equations: 153
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | FAIL | FAIL |
| Run time | 4.68 | 4.64 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.01 s | 1.01 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 3.07 s | 3.06 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 2 | 2 |
| Number NL equation systems | 1 | 1 |
| Largest NL equation system | 1 | 1 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | FAIL | FAIL |
| Task runtime | 0.51 s | 0.51 s |
| Simulation time | 10.00 s | 10.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 1 | 1 |
| State Events | 2 | 2 |
| Jacobian evaluations | 47 | 47 |
| Integrator Steps | 138 | 138 |
| Total CPU time | 0.01 s | 0.01 s |
| CPU time Integration | 0.01 s | 0.01 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank
The model has the same number of unknowns and equations: 153
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank successful.
check - Open log
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank
The model has the same number of unknowns and equations: 153
Check of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank successful.
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank
The DAE has 153 scalar unknowns and 153 scalar equations.
Statistics
Original Model
Number of components: 20
Variables: 281
Constants: 1 (1 scalars)
Parameters: 125 (147 scalars)
Unknowns: 155 (153 scalars)
Differentiated variables: 4 scalars
Equations: 148
Nontrivial: 125
Translated Model
Constants: 84 scalars
Free parameters: 59 scalars
Parameter depending: 50 scalars
Continuous time states: 2 scalars
Time-varying variables: 43 scalars
Alias variables: 65 scalars
Number of mixed real/discrete systems of equations: 2
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {4}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Initialization problem
Number of mixed real/discrete systems of equations: 1
Sizes of nonlinear systems of equations: {4}
Sizes after manipulation of the nonlinear systems: {1}
Sizes of simplified homotopy nonlinear systems of equations: {4}
Sizes after manipulation of the simplified homotopy nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
tank.level
tank.medium.T
Finished
translate - Open log
Translation of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank
The DAE has 153 scalar unknowns and 153 scalar equations.
Statistics
Original Model
Number of components: 20
Variables: 281
Constants: 1 (1 scalars)
Parameters: 125 (147 scalars)
Unknowns: 155 (153 scalars)
Differentiated variables: 4 scalars
Equations: 148
Nontrivial: 125
Translated Model
Constants: 84 scalars
Free parameters: 59 scalars
Parameter depending: 50 scalars
Continuous time states: 2 scalars
Time-varying variables: 43 scalars
Alias variables: 65 scalars
Number of mixed real/discrete systems of equations: 2
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: {4}
Sizes after manipulation of the nonlinear systems: {1}
Number of numerical Jacobians: 0
Initialization problem
Number of mixed real/discrete systems of equations: 1
Sizes of nonlinear systems of equations: {4}
Sizes after manipulation of the nonlinear systems: {1}
Sizes of simplified homotopy nonlinear systems of equations: {4}
Sizes after manipulation of the simplified homotopy nonlinear systems: {1}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
tank.level
tank.medium.T
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
- 1
translate - Largest NL equation system
- 1
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:49:42 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Error: The following error was detected at time: 10.00000000249371
Temperature T (= -15535.2 K) is not
in the allowed range (272.15 K <= T <= 403.15 K)
required from medium model "SimpleLiquidWater".
Failed condition: tank.medium.T >= 272.15 and tank.medium.T <= 403.15
Integration terminated before reaching "StopTime" at T = 10
Final values of states and state derivatives:
State , State value, Derivative value
tank.level , 1.63632e-13, 0.0401773
tank.medium.T, -15535.2, 3.88642e+15
CPU-time for integration : 0.007 seconds
CPU-time for one grid interval : 0.014 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 506
Number of grid points : 502
Number of accepted steps : 138
Number of f-evaluations (dynamics) : 266
Number of crossing function evaluations : 642
Number of Jacobian-evaluations : 47
Number of model time events : 1
Number of input time events : 0
Number of state events : 2
Number of step events : 0
Minimum integration stepsize : 3.79e-14
Maximum integration stepsize : 4.76
Maximum integration order : 4
Calling terminal section
... "dsfinal.txt" creating (final states)
... Error message from dymosim
ERROR: The simulation of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank FAILED
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:03:18 2025)
dymosim started
... "ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Error: The following error was detected at time: 10.00000000249371
Temperature T (= -15535.2 K) is not
in the allowed range (272.15 K <= T <= 403.15 K)
required from medium model "SimpleLiquidWater".
Failed condition: tank.medium.T >= 272.15 and tank.medium.T <= 403.15
Integration terminated before reaching "StopTime" at T = 10
Final values of states and state derivatives:
State , State value, Derivative value
tank.level , 1.63632e-13, 0.0401773
tank.medium.T, -15535.2, 3.88642e+15
CPU-time for integration : 0.009 seconds
CPU-time for one grid interval : 0.018 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 506
Number of grid points : 502
Number of accepted steps : 138
Number of f-evaluations (dynamics) : 266
Number of crossing function evaluations : 642
Number of Jacobian-evaluations : 47
Number of model time events : 1
Number of input time events : 0
Number of state events : 2
Number of step events : 0
Minimum integration stepsize : 3.79e-14
Maximum integration stepsize : 4.76
Maximum integration order : 4
Calling terminal section
... "dsfinal.txt" creating (final states)
... Error message from dymosim
ERROR: The simulation of ModelicaTest.Fluid.TestComponents.Vessels.TestSimpleTank FAILED