Check of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14
The model has the same number of unknowns and equations: 536
Check of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14 successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 5.17 | 5.18 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.03 s | 1.01 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 3.56 s | 3.57 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 8 | 8 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.50 s | 0.52 s |
| Simulation time | 5.00 s | 5.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 4 | 4 |
| State Events | 0 | 0 |
| Jacobian evaluations | 104 | 104 |
| Integrator Steps | 337 | 337 |
| Total CPU time | 0.32 s | 0.31 s |
| CPU time Integration | 0.32 s | 0.31 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14
The model has the same number of unknowns and equations: 536
Check of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14 successful.
check - Open log
Check of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14
The model has the same number of unknowns and equations: 536
Check of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14 successful.
translate - Open log
Translation of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14
The DAE has 536 scalar unknowns and 536 scalar equations.
Statistics
Original Model
Number of components: 67
Variables: 951
Constants: 62 (62 scalars)
Parameters: 344 (352 scalars)
Unknowns: 545 (536 scalars)
Differentiated variables: 16 scalars
Equations: 398
Nontrivial: 306
Translated Model
Constants: 339 scalars
Free parameters: 71 scalars
Parameter depending: 102 scalars
Continuous time states: 8 scalars
Time-varying variables: 125 scalars
Alias variables: 313 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {2, 2, 2, 2}
Sizes after manipulation of the linear systems: {0, 0, 0, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
junctionIdeal.medium.h
junctionIdeal.medium.p
pipe1.mediums[1].h
pipe1.mediums[1].p
pipe2.mediums[1].h
pipe2.mediums[1].p
pipe3.mediums[1].h
pipe3.mediums[1].p
Finished
translate - Open log
Translation of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14
The DAE has 536 scalar unknowns and 536 scalar equations.
Statistics
Original Model
Number of components: 67
Variables: 951
Constants: 62 (62 scalars)
Parameters: 344 (352 scalars)
Unknowns: 545 (536 scalars)
Differentiated variables: 16 scalars
Equations: 398
Nontrivial: 306
Translated Model
Constants: 339 scalars
Free parameters: 71 scalars
Parameter depending: 102 scalars
Continuous time states: 8 scalars
Time-varying variables: 125 scalars
Alias variables: 313 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {2, 2, 2, 2}
Sizes after manipulation of the linear systems: {0, 0, 0, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
junctionIdeal.medium.h
junctionIdeal.medium.p
pipe1.mediums[1].h
pipe1.mediums[1].p
pipe2.mediums[1].h
pipe2.mediums[1].p
pipe3.mediums[1].h
pipe3.mediums[1].p
Finished
translate - Largest NL equation system
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:49:59 2025)
dymosim started
... "ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 5
CPU-time for integration : 0.32 seconds
CPU-time for one grid interval : 0.064 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5006
Number of grid points : 5001
Number of accepted steps : 337
Number of f-evaluations (dynamics) : 694
Number of crossing function evaluations : 5337
Number of Jacobian-evaluations : 104
Number of model time events : 4
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1.85e-10
Maximum integration stepsize : 0.476
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:03:35 2025)
dymosim started
... "ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 5
CPU-time for integration : 0.309 seconds
CPU-time for one grid interval : 0.0618 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5006
Number of grid points : 5001
Number of accepted steps : 337
Number of f-evaluations (dynamics) : 694
Number of crossing function evaluations : 5337
Number of Jacobian-evaluations : 104
Number of model time events : 4
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1.85e-10
Maximum integration stepsize : 0.476
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes14