Check of ModelicaTest.Magnetic.FluxTubes.BasicComponents
The model has the same number of unknowns and equations: 118
Check of ModelicaTest.Magnetic.FluxTubes.BasicComponents successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 4.06 | 4.59 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Magnetic.FluxTubes.BasicComponents\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Magnetic.FluxTubes.BasicComponents\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.03 s | 1.03 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 2.53 s | 3.05 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 3 | 3 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.50 s |
| Simulation time | 14.00 s | 14.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 0 | 0 |
| State Events | 0 | 0 |
| Jacobian evaluations | 44 | 44 |
| Integrator Steps | 138 | 138 |
| Total CPU time | 0.01 s | 0.01 s |
| CPU time Integration | 0.01 s | 0.01 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Magnetic.FluxTubes.BasicComponents
The model has the same number of unknowns and equations: 118
Check of ModelicaTest.Magnetic.FluxTubes.BasicComponents successful.
check - Open log
Check of ModelicaTest.Magnetic.FluxTubes.BasicComponents
The model has the same number of unknowns and equations: 118
Check of ModelicaTest.Magnetic.FluxTubes.BasicComponents successful.
translate - Open log
Translation of ModelicaTest.Magnetic.FluxTubes.BasicComponents
The DAE has 118 scalar unknowns and 118 scalar equations.
Statistics
Original Model
Number of components: 20
Variables: 158
Constants: 1 (1 scalars)
Parameters: 39 (39 scalars)
Unknowns: 118 (118 scalars)
Differentiated variables: 5 scalars
Equations: 103
Nontrivial: 81
Translated Model
Constants: 34 scalars
Free parameters: 23 scalars
Parameter depending: 14 scalars
Continuous time states: 3 scalars
Time-varying variables: 26 scalars
Alias variables: 61 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {5, 3}
Sizes after manipulation of the linear systems: {3, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Initialization problem
Sizes of nonlinear systems of equations: {1}
Sizes after manipulation of the nonlinear systems: {0}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
converter1.i
eddyCurrent.Phi
Dynamically selected continuous time states
There is one set of dynamic state selection.
There is one state to be selected from:
converter.i
converter.Phi
leakageWithCoefficient.port_p.Phi
Finished
translate - Open log
Translation of ModelicaTest.Magnetic.FluxTubes.BasicComponents
The DAE has 118 scalar unknowns and 118 scalar equations.
Statistics
Original Model
Number of components: 20
Variables: 158
Constants: 1 (1 scalars)
Parameters: 39 (39 scalars)
Unknowns: 118 (118 scalars)
Differentiated variables: 5 scalars
Equations: 103
Nontrivial: 81
Translated Model
Constants: 34 scalars
Free parameters: 23 scalars
Parameter depending: 14 scalars
Continuous time states: 3 scalars
Time-varying variables: 26 scalars
Alias variables: 61 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: {5, 3}
Sizes after manipulation of the linear systems: {3, 0}
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Initialization problem
Sizes of nonlinear systems of equations: {1}
Sizes after manipulation of the nonlinear systems: {0}
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
converter1.i
eddyCurrent.Phi
Dynamically selected continuous time states
There is one set of dynamic state selection.
There is one state to be selected from:
converter.i
converter.Phi
leakageWithCoefficient.port_p.Phi
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:52:46 2025)
dymosim started
... "ModelicaTest.Magnetic.FluxTubes.BasicComponents" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 14
CPU-time for integration : 0.011 seconds
CPU-time for one grid interval : 0.00236 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 4668
Number of grid points : 4667
Number of accepted steps : 138
Number of f-evaluations (dynamics) : 253
Number of Jacobian-evaluations : 44
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1.09e-14
Maximum integration stepsize : 1.01
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Magnetic.FluxTubes.BasicComponents
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:06:21 2025)
dymosim started
... "ModelicaTest.Magnetic.FluxTubes.BasicComponents" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 14
CPU-time for integration : 0.01 seconds
CPU-time for one grid interval : 0.00214 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 4668
Number of grid points : 4667
Number of accepted steps : 138
Number of f-evaluations (dynamics) : 253
Number of Jacobian-evaluations : 44
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1.09e-14
Maximum integration stepsize : 1.01
Maximum integration order : 5
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Magnetic.FluxTubes.BasicComponents