Check of ModelicaTest.Media.TestAllProperties.SimpleAir
The model has the same number of unknowns and equations: 56
Check of ModelicaTest.Media.TestAllProperties.SimpleAir successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 3.65 | 3.61 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Media.TestAllProperties.SimpleAir\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Media.TestAllProperties.SimpleAir\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.52 s | 0.53 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 2.55 s | 2.53 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 0 | 0 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.50 s | 0.51 s |
| Simulation time | 0.10 s | 0.10 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 1 | 1 |
| State Events | 0 | 0 |
| Jacobian evaluations | 31 | 31 |
| Integrator Steps | 33 | 33 |
| Total CPU time | 0.00 s | 0.00 s |
| CPU time Integration | 0.00 s | 0.00 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Media.TestAllProperties.SimpleAir
The model has the same number of unknowns and equations: 56
Check of ModelicaTest.Media.TestAllProperties.SimpleAir successful.
check - Open log
Check of ModelicaTest.Media.TestAllProperties.SimpleAir
The model has the same number of unknowns and equations: 56
Check of ModelicaTest.Media.TestAllProperties.SimpleAir successful.
translate - Open log
Translation of ModelicaTest.Media.TestAllProperties.SimpleAir
The DAE has 56 scalar unknowns and 56 scalar equations.
Statistics
Original Model
Number of components: 9
Variables: 62
Constants: 2 (2 scalars)
Parameters: 3 (3 scalars)
Unknowns: 57 (56 scalars)
Equations: 57
Nontrivial: 51
Translated Model
Constants: 60 scalars
Free parameters: 1 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Finished
translate - Open log
Translation of ModelicaTest.Media.TestAllProperties.SimpleAir
The DAE has 56 scalar unknowns and 56 scalar equations.
Statistics
Original Model
Number of components: 9
Variables: 62
Constants: 2 (2 scalars)
Parameters: 3 (3 scalars)
Unknowns: 57 (56 scalars)
Equations: 57
Nontrivial: 51
Translated Model
Constants: 60 scalars
Free parameters: 1 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:50:40 2025)
dymosim started
... "ModelicaTest.Media.TestAllProperties.SimpleAir" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 0.1
CPU-time for integration : 0.003 seconds
CPU-time for one grid interval : 0.0006 milliseconds
CPU-time for initialization : 0 seconds
Number of result points : 5003
Number of grid points : 5001
Number of accepted steps : 33
Number of f-evaluations (dynamics) : 33
Number of Jacobian-evaluations : 31
Number of model time events : 1
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1e-09
Maximum integration stepsize : 0.0398
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Media.TestAllProperties.SimpleAir
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:04:14 2025)
dymosim started
... "ModelicaTest.Media.TestAllProperties.SimpleAir" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 0.1
CPU-time for integration : 0.003 seconds
CPU-time for one grid interval : 0.0006 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5003
Number of grid points : 5001
Number of accepted steps : 33
Number of f-evaluations (dynamics) : 33
Number of Jacobian-evaluations : 31
Number of model time events : 1
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 1e-09
Maximum integration stepsize : 0.0398
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Media.TestAllProperties.SimpleAir