Check of ModelicaTest.Media.TestOnly.MixIdealGasAir
The model has the same number of unknowns and equations: 47
Check of ModelicaTest.Media.TestOnly.MixIdealGasAir successful.
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Testrun ID | 20250225034436 | 20250225005809 |
| Simulator | Dymola | Dymola |
| Status | PASS | PASS |
| Run time | 5.07 | 5.57 |
| Workdir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest_org\ModelicaTest.Media.TestOnly.MixIdealGasAir\WorkDir | D:/MSL_Nightly/Output/Testruns/Dymola/ModelicaTest\ModelicaTest.Media.TestOnly.MixIdealGasAir\WorkDir |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 1.01 s | 1.04 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 3.55 s | 4.03 s |
| Warnings | 0 | 0 |
| Errors | 0 | 0 |
| Open log  | Open log  | |
| Numerical Jacobians | 0 | 0 |
| Continuous time states | 6 | 6 |
| Number NL equation systems | 0 | 0 |
| Largest NL equation system | 0 | 0 |
| ModelicaTest410 experiment tolerance | ModelicaTest410 tightend tolerance | |
|---|---|---|
| Status | PASS | PASS |
| Task runtime | 0.51 s | 0.50 s |
| Simulation time | 1.00 s | 1.00 s |
| Copy result file path  | Copy result file path  | |
| Open log  | Open log  | |
| Time Events | 0 | 0 |
| State Events | 0 | 0 |
| Jacobian evaluations | 22 | 22 |
| Integrator Steps | 23 | 23 |
| Total CPU time | 0.04 s | 0.05 s |
| CPU time Integration | 0.04 s | 0.05 s |
| CPU time Initialization | 0.00 s | 0.00 s |
check - Open log
Check of ModelicaTest.Media.TestOnly.MixIdealGasAir
The model has the same number of unknowns and equations: 47
Check of ModelicaTest.Media.TestOnly.MixIdealGasAir successful.
check - Open log
Check of ModelicaTest.Media.TestOnly.MixIdealGasAir
The model has the same number of unknowns and equations: 47
Check of ModelicaTest.Media.TestOnly.MixIdealGasAir successful.
translate - Open log
Translation of ModelicaTest.Media.TestOnly.MixIdealGasAir
The DAE has 47 scalar unknowns and 47 scalar equations.
Statistics
Original Model
Number of components: 9
Variables: 84
Constants: 40 (96 scalars)
Parameters: 4 (4 scalars)
Unknowns: 40 (47 scalars)
Differentiated variables: 6 scalars
Equations: 44
Nontrivial: 38
Translated Model
Constants: 109 scalars
Continuous time states: 6 scalars
Time-varying variables: 32 scalars
Alias variables: 6 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
medium.p
medium.T
medium2.p
medium2.T
medium2.X[1]
medium2.X[2]
Finished
translate - Open log
Translation of ModelicaTest.Media.TestOnly.MixIdealGasAir
The DAE has 47 scalar unknowns and 47 scalar equations.
Statistics
Original Model
Number of components: 9
Variables: 84
Constants: 40 (96 scalars)
Parameters: 4 (4 scalars)
Unknowns: 40 (47 scalars)
Differentiated variables: 6 scalars
Equations: 44
Nontrivial: 38
Translated Model
Constants: 109 scalars
Continuous time states: 6 scalars
Time-varying variables: 32 scalars
Alias variables: 6 scalars
Number of mixed real/discrete systems of equations: 0
Sizes of linear systems of equations: { }
Sizes after manipulation of the linear systems: { }
Sizes of nonlinear systems of equations: { }
Sizes after manipulation of the nonlinear systems: { }
Number of numerical Jacobians: 0
Settings
Advanced.StoreProtectedVariables = true
Selected continuous time states
Statically selected continuous time states
medium.p
medium.T
medium2.p
medium2.T
medium2.X[1]
medium2.X[2]
Finished
translate - Continuous time states
translate - Continuous time states
translate - Largest NL equation system
translate - Largest NL equation system
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 03:50:47 2025)
dymosim started
... "ModelicaTest.Media.TestOnly.MixIdealGasAir" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1
CPU-time for integration : 0.039 seconds
CPU-time for one grid interval : 0.0078 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 23
Number of f-evaluations (dynamics) : 23
Number of crossing function evaluations : 5023
Number of Jacobian-evaluations : 22
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 2e-07
Maximum integration stepsize : 0.419
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Media.TestOnly.MixIdealGasAir
simulate - Open log
Log-file of program ./dymosim
(generated: Tue Feb 25 01:04:23 2025)
dymosim started
... "ModelicaTest.Media.TestOnly.MixIdealGasAir" simulating
... "dsin.txt" loading (dymosim input file)
... "result.mat" creating (simulation result file)
Integration started at T = 0 using integration method DASSL
(DAE multi-step solver (dassl/dasslrt of Petzold modified by Dassault Systemes))
Integration terminated successfully at T = 1
CPU-time for integration : 0.047 seconds
CPU-time for one grid interval : 0.0094 milliseconds
CPU-time for initialization : 0.001 seconds
Number of result points : 5002
Number of grid points : 5001
Number of accepted steps : 23
Number of f-evaluations (dynamics) : 23
Number of crossing function evaluations : 5023
Number of Jacobian-evaluations : 22
Number of model time events : 0
Number of input time events : 0
Number of state events : 0
Number of step events : 0
Minimum integration stepsize : 2e-07
Maximum integration stepsize : 0.419
Maximum integration order : 1
Calling terminal section
... "dsfinal.txt" creating (final states)
SUCCESSFUL simulation of ModelicaTest.Media.TestOnly.MixIdealGasAir